View Connector Properties and Field Definitions
Archibus Extensions for BUILDER™ SMS
View Connector Properties and Field Definitions
Three master connectors move asset data between Archibus and BUILDER™ SMS. Each master connector comprises a group of inbound or outbound connectors.
Select a Connector to View or Edit
To view or edit information for a master connector, or for an individual inbound or outbound connector:
- Launch Web Central.
-
Select:
System / System Administrator / Configure Connectors (
afm-connector-define-tabs.axvw
)The Select a Connector to View/Edit tab opens.
-
Locate the desired connector.
For example, enter sms under Connector Code , then press Enter, to list three master connectors. Alternately, select SQL Server under Connector Type to list individual connectors.
- Click the desired connector to open the connector's Properties tab.
See Configure Master Connectors for more information about connector properties.
Note: Typically you will modify properties only for the master connectors, not for individual connectors in a group.
View Inbound or Outbound Connectors
To display properties for inbound or outbound connectors:
-
Open the Select Connector to View/Edit tab in System / System Administrator / Configure Connectors (
afm-connector-define-tabs.axvw
), then select SQL Server in the Connector Type drop-down list.All SQL Server connectors appear, including BUILDER™ SMS master connectors at the end of the list.
-
Click the desired connector.
The Properties tab for the selected connector opens.
To open a list of all inbound connectors in SMS_Builder_to_Archibus_Assets :
- Type in- under Connector Code , then press Enter.
- Click the desired connector name to open Define Connector Properties for that connector.
To open a list of all outbound connectors in SMS_Archibus_to_Builder_Assets :
- Type out- under Connector Code , then press Enter.
- Click the desired connector name to open Define Connector Properties for that connector.
View Connector Properties and Connector Fields
For any individual connector listed in the Select a Connector to View/Edit tab, click the connector to open the Properties tab for that connector. Note these properties, besides Connector Code at the top:
- Archibus Table
- Remote Source
- Connection String
Click the Fields tab to open Define Connector Fields . All the fields listed are related to the connector listed under Connector Code .
For each field the connector handles during a data transfer, note the field names under Source Field and Destination Fields . The field names show, for any transfer, where an item originates in the source data table, and where it lands in the destination table.
Note: Names for equivalent fields in Archibus and BUILDER™ SMS often differ. Refer to Equivalent Terms , or to field tooltips in the Archibus interface.
See also